| Advertisement ID | : | 1753425 |
| Category | : | Other Items |
| Ads Classification | : | For Sale |
| Condition | : | Brand New |
| Warranty | : | Shop / Factory Warranty |
| Date Posted | : | November 8, 2009 |
| Short URL | : | http://sulit.com.ph/1753425 |
| CableAnalyzer Model:CN60M/DTX-LT | Item: |
Products Superior to IV level test accuracy beyond the standard requirement Cat 5e/6/7 Complete a Cat 6 Auto test requires only 12 seconds faster than the previous Test at least three times Fault diagnosis of advanced time-saving ability to be able to pinpoint failures, but also provide repair recommendations 900MHz frequency range, in order to prepare for your future applications. For example, Gigabit Ethernet, Class F links or CATV Bei Cha-type optical module, one-touch can be tested in the copper and fiber cable to switch between DTX significantly reduces the overall cost of certification testing, an annual savings of up to 335 of the overhead Function CableAnalyzer greatly shortening the certification test of time. Complete a six category link automatic test of time three times faster than other devices - for cable certification test 5 times faster. Which is just the beginning, DTX series also has a level IV accuracy unmatched intelligent fault diagnostic capability, 900MHz of testing bandwidth, 12-hour battery life and fast instrument settings, and can generate detailed graphical test reports in Chinese. With the help of the test instrument, you have the best tools to solve the problem, and any challenge to face the future ready. Features Analyzer using the coaxial cable certification test adapter can be quickly and easily test coaxial cable link. Analyzer DTX series cable certification test coaxial cable systems to increase functionality, including the generation of data cable (such as 10BASE-2 or 10BASE-5 Ethernet) and video distribution coaxial cable, function has been further enhanced. Fluke Networks, a new coaxial cable test adapter and upgrade software for your DTX Series CableAnalyzer an increase of coaxial cable test function as follows: Length Latency Cable (input) impedance As a function of signal frequency insertion loss Cable impedance Cable input impedance for the characterization of coaxial cable would be the right type, such as for the previous generation Ethernet systems 75Ω cable and 50Ω cables or 93Ω cables. In addition, the test instrument on the link the implementation of time domain reflectometry (TDR) test to ensure that the cable does not occur on the impedance characteristics change significantly. Impedance anomaly would lead to serious signal transmission quality. Latency Propagation delay measurement signal from one end to the other end of the cable links the time required. Cable NVP value is the speed of electric signals on the cable, which is used to convert the link propagation delay "electrical length." How to NVP value enough precision, then the electrical length will be close to the physical length. Insertion Loss With the DTX Coax Test Adapter, DTX-1800 can be from 1 to 900 MHx within the frequency range of coaxial cable insertion loss measurements. DTX-1200 using the coaxial cable adapter can be from 1 to 350 MHz frequency range measured insertion loss. Download DTX 1.1 version of the software and LinkWare cable test results management software 2.3 version, you can for your DTX series cable certification testers to increase coaxial cable testing. Recommended to all of the DTX Series tester for software upgrades, regardless of whether you use the coaxial cable test adapter. The new PM06 Personality Module Use Fluke Networks PM06 test plug superior in perspective for your Cat 6 cabling systems for adaptability and interoperability. PM06 cable industry's first test of a central shield plug. It has taken a global connector manufacturer of industrial recognition, a unique center link and the plug can be certified Cat 6 connecting hardware compliance standards, in order to achieve "open" the cable system. It supports all UTP, FTP, and ScTP cable system. Neutral TIA / ISO plugs Shield - a global solution Manufacturers are not bound by Then buckle concealed handle To ensure the interoperability of end-user Socket can be used for hidden PM06 is the industry's only standards-compliant central Cat 6 test plug has been recognized by many manufacturers The new neutral plug design PM06 unique design in full compliance with the standard definition of Cat 6 components of the indicators and standards defined in the center of the performance range (37dB). This design ensures availability of all PM06 modules can get the best test results and the smallest variability. Consistency of test results will allow you a fair and reliable cable solutions for different performance comparison. * TIA defines plug 3,6-4,5 pairs range from 36.4 Dao 37.6 dB. Center refers to the value located in the middle of the range: 37 dB. On the DSP-PM25 Currently meet the TIA standard DSP-PM25 will eventually be eliminated, mainly because it applies only to test non-shielded cable. DSP-PM06 is not only the TIA / ISO center test plugs, but also shielded plug (UTP / FTP / STP) generic solution (UTP / FTP / STP), meet all market needs. DSP-PM25 is still applicable to test non-shielded cable. Users can also choose to continue to use existing DSP-PM25, instead of using DSP-PM06. DTX Series Cable Analyzer to obtain UL accuracy of certification Certification Fluke Networks DTX Series Cable Analyzer is the first certified and only one access to the latest standards UL certified cable testing equipment. DTX Series Cable Analyzer certified the accuracy of the standard adopted by UL (Underwriters Laboratories) and accuracy of certification, the certification is based on IEC-61935-1 standards for Class IV accuracy requirements and TIA-TSB-155 standard-level accuracy for the IIIe proposal and to get. IIIe-level accuracy will be required to test for the deployment of 10GB Ethernet Cat 6 cables. UL certification can provide to users a trusted, neutral advice, the certification would be whether the product is in full compliance with industry standards and a rigorous assessment of relevant indicators. UL tests products from Fluke Networks stock randomly selected several cable tester to assess, so that to ensure the authenticity of the test. Very noteworthy point is that DTX Series Cable Analyzer passed all certification standards, including the baseline test instrument, permanent link and channel measurement configuration requirements. Accuracy allows users confidence in the test results. It can be installed to the network owners to ensure the cable link is indeed in line with their expected performance. Accuracy can help you save time and expense. Certification testing was conducted using the DTX will not be wrong "through" and "failure" results. Construction of high-performance cable system technology standards is increasing, the error of the critical value of getting smaller and smaller. Fluke Networks can provide you with proven performance guarantees. Use LinkWare cable test management software saves time for the management of test results DTX series cable certification g network analyzer with the powerful LinkWare cable management software, which can help you to quickly test results through the workplace, users, and architecture to organize, edit, view, print, save or archive. You can merge test results into the existing database, by any data fields or parameters to sort, search or organization. You can choose from our web site for free download LinkWare software, once you have completed the work, you can use this powerful program presented to your users, so that they can immediately access the electronic data, you can also just data Export to Adobe's PDF documents. LinkWare a wide range of data management software capabilities: Software management using a single copper and fiber test results support the full range of Fluke Networks cable testers For all Fluke Networks cable testers in a common format to be a professional graphic test reports To ensure compliance with configuration and print TIA 606-A standards document The new drag and drop functionality makes it easier to manage and organize multiple projects And powerful CMS Cable Management Software compatibility A simple user interface and time-saving features to improve productivity, it is the world's preferred cable test management software LinkWare color graphic description of the software measured parameters, you can print professional, graphical test reports. You can choose to print what parameters and graphical display order. You can customize the report on the company's LOGO. The new LinkWare Stats report statistics option provides all of your graphical analysis of cable equipment LinkWare now supports the report LinkWare Stats statistical software, which is a new automated statistical report option, it goes beyond the individual links generate test reports, but look at your entire cable structure. Will LinkWare cable test data analysis and converted to graphics, to compact, graphical format, showing you the entire cable structure, cable equipment, a summary of the performance, so you can easily verify that border, found nothing unusual. LinkWare Stats to see how to deal with your data - LinkWare cable management software with free DEMO version of LinkWare Stats. Permanent link test adapter technology reduces the miscarriage of justice Commercial jumpers - including the super-five classes, six classes as well as seven classes - if they are directly used to test the permanent link, the link will result in many qualified misjudgment, wasting a lot of time for diagnosis of failure and repeat the test. Due to the repeated curl jumper and started, as well as on-site environment, careless storage and so the daily wear and tear, will lead to reduced performance over time, the most obvious is the impact of return loss, which are usually caused by the reasons for test failure . 2 times faster fault diagnosis When there is a link failure, DTX Series tester can provide quick and easily understandable way, to indicate the exact fault location (fault point to the distance from the tester), and the possible reasons for failure. These tips not only tell you what the fault occurred, but also gives you the right way to resolve issues quickly - so no need to spend time to consult the ability of project personnel. Do not waste time to experiment, and explore the troubleshooting methods, and re-test to determine whether the failure to solve - testers to be able to clearly know where the link failure occurred, what kind of problem and needs to be able to do troubleshooting . Even in a day's work, only 2% of the problems with the link being tested, you can save 2 hours of time. Testing for the future needs of the 900MHz frequency DTX Series CableAnalyzer top model - DTX-1800 - supports up to 900MHz of testing frequency. This high-bandwidth to support the requirements of ISO Class F links, and meet to run Gigabit Ethernet twisted-pair tests. It can also help you to link to other certification applications, such as twisted-pair cabling systems in the video transmission. In the market, no other test is compatible with Ultra 5 class 6 class testing requirements while still protecting your investment to meet the future needs. Cabling vendors recognized When you decided to test the instrument, vendor recognition is necessary. With the manufacturers warranty, you should use the test tool also accredited to conduct certification testing, so that users can ensure that your satisfaction. customers' complete satisfaction. The characteristics of DTX 12-second Cat 6 Auto test Faster than other testers three times as Level IV Accuracy Beyond the six classes and higher standards of the indicator Advanced rapid fault diagnosis technology Pinpoint the location of link failures in an arbitrary and offer to help you troubleshooting the right way. Environment for the permanent on-site link adapter To provide high accuracy and repeatability of testing with the six class system compatibility 12-hour battery life Lithium-ion battery for a full day of work motivation Readily available fiber optic modules DTX Series Beicha-style slots for optional fiber optic module fiber optic cable to provide protection module 12 seconds of fiber optic cable automatic test Simultaneous pairs of dual-wavelength fiber certification test Internal Memory Can save more than 250 graphic formats or 2000, the provisions of this format, category 6 link test report Card For rapid processing of data - 16MB memory card can save 300 graphics formats, category 6 link test report Test bandwidth of up to 900MHz Support video transmission, Class F, or Gigabit Ethernet applications Color large screen display With a high-brightness background light, easy to observe the test result data USB port High-speed download test data Store all the test results graphic By Fluke Networks LinkWare software downloaded to the PC machine Lightweight portable, ergonomic design Very suitable for field use Built-in intercom function So you can peer through the twisted-pair or fiber optic cable at both ends of the link exchange. Knob switch Easy to learn, and easy operation You always know that the selected test mode Solid jacket Be able to meet a variety of field environments use requirements Parameters Baseline Accuracy DTX Series testers for all their support in the frequency range have met or exceeded the IEC61935-1 version 2 of the draft Level IV accuracy Category 6 / E link-level test pattern (including the lower link type) DTX Series testers TIA/EIA-568-B.2-2 standard and far exceeded the standard requirements of IEC61935-1 Class III accuracy F Grade Link Test Mode DTX-1800 to meet the IEC61935-1 version 2 of the draft Level IV accuracy The length of twisted-pair test (Length specs do not include the uncertainty of the cable's NVP Value) Range 800 m - Single-ended Test 150 m - double-ended test (the host and remote) Resolution 0.1 m - Single-ended Test 0.1 m - double-ended test (the host and remote) Accuracy (1m 4%) - Single-ended Test (1m 4%) - double-ended test (the host and remote) Parameters Twisted-pair link Range 0 ns to 100 ns Resolution 1 ns Accuracy 10ns Parameters Twisted-pair link Range O to 53 Resolution 0.1 Accuracy 1% Overload recovery time Overvoltage within 10 minutes after the resumption of the relevant accuracy. If the pressure is repeated several times over a long time or you need to calibrate | CableAnalyzer CN60M/DTX-LT![]() |
| Posted by | : | maia1980 |
| Member Since | : | October 9, 2008 |
| Last Login | : | 21 hours, 25 minutes ago |
| Feedback | : | no feedback yet |
| Address | : | Beijing China |
| Contact Nos. | : | +8613901136645, 09085675878 |
| Look For | : | Midwest Group |
Discussion RSS Feeds ] 
